SerReset
SerReset
Reset and initial specified input or output drivers short refNum ; reference number of driver to be reset/ initialized
short SerConfig ; integer that determines configuration
SerReset resets and initializes either an input driver or an output driver with a new communications configuration.
refNum identifies the input or output driver being reset and initialized.
serConfig is a predefined constant for information such as data rate, parity,
number of data bits, and number of stop bits.
noErr (0) No error
Notes: SerReset's constants are defined as:
baud300 (380) Transmission rate = 300 bits per second
baud600 (189) Transmission rate = 600 bits per second
baud1200 (94) Transmission rate = 1200 bits per second
baud1800 (62) Transmission rate = 1800 bits per second
baud2400 (46) Transmission rate = 2400 bits per second
baud3600 (30) Transmission rate = 3600 bits per second
baud4800 (22) Transmission rate = 4800 bits per second
baud7200 (14) Transmission rate = 7200 bits per second
baud9600 (10) Transmission rate = 9600 bits per second
baud19200 (4) Transmission rate = 19200 bits per second
baud57600 (0) Transmission rate = 57600 bits per second
stop10 (16384) Indicates 1 stop bit
stop15 (-32768) Indicates 1.5 stop bits
stop20 (-16384) Indicates 2 stop bits
noParity (0) No parity
oddParity (2048) Odd parity
evenParity (1024) Even parity
data5 (0) 5 data bits
data6 (2048) 6 data bits
data7 (1024) 7 data bits
data8 (3072) 8 data bits
These values are used in the serConfig integer, formatted as:
and csParam=SerConfig.